Biolinkk

EC/TDS/NaCl/Temp Logging Bench Meter (MW170)

The Milwaukee MW170 4-in-1 MAX EC/TDS/NaCl/Temp. Logging Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design and small benchtop footprint.

Highlights

  • RANGE EC: 0.00 to 29.99 uS/cm / 30.0 to 299.9 uS/cm | 300 to 2999 uS/cm | 3.00 to 29.99 mS/cm | 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute conductivity)*
  • RANGE TDS: 0.00 to 14.99 ppm (mg/L) | 15.0 to 149.9 ppm (mg/L) | 150 to 1499 ppm (mg/L) | 1.50 to 14.99 g/L | 15.0 to 100.0 g/L | up to 250.0 g/L absolute TDS** | up to 400 g/L (absolute TDS** with 0.80 factor)
  • RANGE SALINITY: 0.0 to 400.0 % Nacl | 2.00 to 42.00 PSU | 0.00 to 80.00 g/L
  • RANGE TEMPERATURE: -20.0 to 120.0°C | -4.0 to 248.0°F

Product Overview

Description

It is accurate to ± 1% of reading for EC/TDS & Salinity with automatic, manual or no temperature compensation and a built in dedicated GLP key. Ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging EC/TDS/NaCL/Temp. measurement needs.

The Milwaukee MW170 4-in-1 MAX EC/TDS/NaCl/Temp. Logging Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design and small benchtop footprint. It is accurate to ± 1% of reading for EC/TDS & Salinity with automatic, manual or no temperature compensation and a built in dedicated GLP key. Ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging EC/TDS/NaCL/Temp. measurement needs.

Features

  • Fast easy to read results with large duel level digital LCD readout.
  • Extreme accuracy to 1% of reading for EC/TDS/NaCl |+/- 0.5°C (+/-0.9°F). 
  • Extended auto-ranging feature for EC/TDS/NaCl.
  • Lightweight, sleek design featuring a small benchtop footprint.
  • Simple easy-to-use logging; manual log-on-demand or manual log-on-stability up to 1,000 records.  
  • Micro USB Port download functions. 
  • GLP data, date and time.
  • Easy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize.
  • Single cell factor calibration for EC/TDS/NaCl, automatic simple one point calibration and two point for temperature allowing increased accuracy.
  • Rugged low maintenance, high performance, easy-to-clean EC/TDS/NaCL/Temp probe.
  • Built in temperature sensor. 
  • Internal clock date to keep track of different time-dependent functions (calibration, timestamp,calibration time out).
  • 3 feet probe cables for extra flexibility when testing.
  • Includes MA9315 electrode holder, cables, adapter and probe.

Specifications

EC Range 0.00 to 29.99 uS/cm / 30.0 to 299.9 uS/cm
EC Range 300 to 2999 uS/cm
EC Range 3.00 to 29.99 mS/cm / 30.0 to 200.0 mS/cm
EC Range up to 500 mS/cm absolute conductivity**
TDS Range 0.00 to 14.99 ppm (mg/L)
TDS Range 15.0 to 149.9 ppm (mg/L) / 150 to 1499 ppm (mg/L)
TDS Range 1.50 to 14.99 g/L / 15.0 to 100.0 g/l
TDS Range upt to 250.0 g/L absolute TDS**
TDS Range up to 400 g/L absolute TDS** (with 0.80 factor)
Salinity Range 0.0 to 400.0% NaCl / 2.00 to 42.00 PSU
Salinity Range 0.00 to 80.00 g/L
Temp. Range -20.0 to 120.00°C (-4.0 to 248.0°F)
EC Resolution 0.01 uS/cm / 0.1 uS/cm / 1 uS/cm
EC Resolution 0.01 mS/cm / 0.1 mS/cm
TDS Resolution 0.01 ppm / 0.1 ppm / 1 ppm
TDS Resolution 0.01 g/L / 0.1 g/L
Salinity Resolution 0.1% NaCl / 0.01 PSU / 0.01 g/L
Temperature Resolution 0.1°C / 0.1°F)
Accuracy @ 25°C / 77°F
EC ± 1% of reading / ±0.05 uS/cm or 1 digit, whichever is greater
TDS ±1% of reading / ±0.03 ppm or 1 digit, whichever is greater
Salinity ±1% of reading
Temperature ±0.5°C (±0.9°F)
Calibration
EC/TDS single cell factor calibration, 6 standards
Salinity one point with MA9066 salinity calibration solution
Temperature Compensation Automatic or manual from -20 to 120°C (-4.0 to 248.0°F) or NO TC without temperature compensation
Conductivity temperature coefficient 0.00 to 6.00 % / °C (EC and TDS only) | Default value
TDS factor 0.40 to 0.80 / Default value
EC Probe MA814DB/1 4 ring
Temperature probe Built-in temperature sensor
Logging Maximum 1,000 log records (stored in up to 100 lots) / on demand, 200 logs on stability, 200 logs, interval logging 1000
PC Connectivity 1 micro USB port
Power Supply 12 VDC adapter (included)
Battery Type Internal
Battery life Approx. 8 hours of use
Environment 0 to 50°C / 32 to 122°F; max RH 95%
Dimensions 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
Weight 0.9 kg / 2.00 lbs.